(1) Main current IH adjuster ... for stepless adjustment of the welding current
(2) AC arc frequency adjuster ... for changing the arc concentration
(3) Balance adjuster ... for changing the positive and negative half-wave in the
MMA and TIG AC range.
Important! When using the remote control for manual metal arc welding in the AC or DC
range, the values set in the device apply for the HotStart current, HotStart time and
dynamics. (Chapter "Program level preferences")
TIG pulse remote
control TR 50mc
Connect the TIG pulse remote control to the LocalNet connection socket.
- TIG pulse welding indicator (1) flashes as soon as the remote control is connected.
Two operating modes are possible with the TR 50mc pulse remote control:
- Pulse current regulation I1 on remote control TR 50mc
- Pulse current regulation I1 with foot remote control TR 52mc
TIG pulse remote control TR 50mc
(1) Adjuster for pulse current I
1
... for stepless adjustment of the pulse main current
(2) Adjuster for pulse frequency f ... for stepless adjustment of the pulse fre-
quency depending on the preselected frequency range (5)
(3) Adjuster for base current I
2
... for percentage adjustment of the base current
from the set value of the pulse current I
1
(1)
(4) Adjuster for duty cycle dcY ... for percentage adjustment of the ratio between
the pulse current phase and the base current phase.
Setting example for low heat input:
Duty cycle adjuster in position "10"
- Short pulsing current phase of 10%
- Long base current phase of 90%
(5) Adjuster for frequency range ... for step-by-step pre-selection of the desired
frequency
Setting ranges:
50