Service, maintenance and disposal
General The power source only requires minimal care and maintenance under normal operating
conditions. However, some important points must be noted to ensure that the welding
system remains in a usable condition for many years.
WARNING!
Danger of electric shock.
This can result in severe personal injury and damage to property.
▶
Set the power switch to the "O" position
▶
Unplug the device from grid power
▶
Attach a clear warning sign advising others not to switch the power source back on
▶
Use a suitable measuring instrument to ensure that electrically charged components
(e.g., capacitors) are discharged
At every start-up - Check mains plug and mains cable, as well as the welding torch, interconnecting
hosepack, and ground earth connection for damage
- Check if the all-round clearance of the device is 0.5 m (1 ft. 7 in.) so that cooling air
can circulate unimpeded
NOTE!
Air intake and exhaust openings must also not be blocked or even partially
covered.
Every 2 months - If present: clean air filter
Every 6 months - Dismantle device side panels and blow the inside of the device clean with dry,
reduced compressed air
NOTE!
Risk of damage to electronic parts. Do not bring the air nozzle too close to elec-
tronic parts.
- Also clean the cooling air ducts if there is a large accumulation of dust
Disposal Materials should be disposed of according to valid local and national regulations.
Spare parts - MagicWave 2600
- MagicWave 3000
- TransTig 2600
- TransTig 3000