- (OU01 - 07) -
Outdoor unit / Single phase
OUTDOOR UNIT
WO
A060-100LF
OUTDOOR UNIT
WO
A060-100LF
PRODUCT INFORMATION2-4.
Product information according to Commission Delegated Regulation (EU) 813/2013
Product information is based on the average climate condition.
Model
Hydraulic unit
WSYA050DG6
WSHA050DG *1
WGYA050DG6
WGHA050DG *1
WSYA100DG6
WSHA100DG *1
WGYA100DG6
WGHA100DG *1
Outdoor unit
WOYA060LFCA
WOHA060LFCA
WOYA060LFCA
WOHA060LFCA
Air-to-water heat pump Yes
Water-to-water heat pump No
Brine-to-water heat pump No
Low-temperature heat pump No
Equipped with a supplementary heater Yes
Heat pump combination heater Yes
Temperature application °C 55
35
55
35
55
35
55
35
Rated heat output *2
Prated
kW 4 4 4 4 5 5 5 5
Seasonal space heating energy efciency ƞ
s % 115 169 115 169 115 169 115 169
Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature T
j
Tj = –7 °C Pdh kW 3.8 4.0 3.8 4.0 4.0 4.6 4.0 4.6
T
j = +2 °C Pdh kW 2.3 2.4 2.3 2.4 2.5 2.8 2.5 2.8
T
j = +7 °C Pdh kW 1.7 2.0 1.7 2.0 1.7 2.3 1.7 2.3
T
j = +12 °C Pdh kW 2.1 2.3 2.1 2.3 2.1 2.3 2.1 2.3
T
j = bivalent temperature Pdh kW 3.8 4.0 3.8 4.0 4.0 4.6 4.0 4.6
T
j = operation limit temperature Pdh kW 3.2 3.9 3.2 3.9 3.5 4.5 3.5 4.5
T
j = –15 °C (if TOL < –20 °C) Pdh kW - - - - - - - -
Bivalent temperature T
biv °C -7 -7 -7 -7 -7 -7 -7 -7
Cycling interval capacity for heating P
cych kW Not applicable
Degradation co-efcient *3 Cdh — 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9
Declared coefcient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature T
j
Tj = –7 °C
COPd
— 1.86 2.86 1.86 2.86 1.79 2.65 1.79 2.65
T
j = +2 °C
COPd
— 2.82 4.10 2.82 4.10 2.86 4.17 2.86 4.17
T
j = +7 °C
COPd
— 4.00 5.90 4.00 5.90 4.03 5.99 4.03 5.99
T
j = +12 °C
COPd
— 5.84 8.12 5.84 8.12 5.84 8.29 5.84 8.29
T
j = bivalent temperature
COPd
— 1.86 2.86 1.86 2.86 1.79 2.65 1.79 2.65
T
j = operation limit temperature
COPd
— 1.54 2.65 1.54 2.65 1.56 2.57 1.56 2.57
T
j = –15 °C (if TOL < –20 °C)
COPd
— - - - - - - - -
Operation limit temperature TOL °C -10 -10 -10 -10 -10 -10 -10 -10
Cycling interval efciency
COPcyc
— Not applicable
Heating water operating limit temperature
WTOL
°C 55 55 55 55 55 55 55 55
Power consumption in modes other than active mode
Off mode P
OFF kW 0.006 0.006 0.006 0.006 0.006 0.006 0.006 0.006
Thermostat-off mode P
TO kW 0.016 0.019 0.016 0.019 0.016 0.023 0.016 0.023
Standby mode P
SB kW 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010
Crankcase heater mode P
CK kW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Supplementary heater
Rated heat output *2 P
sup kW 1.1 0.6 1.1 0.6 1.0 0.7 1.0 0.7
Type of energy input Electric
Other items
Capacity control Variable
Sound power level
Indoor unit L
WA dB 46 46 46 46 46 46 46 46
Outdoor unit L
WA dB 65 60 65 60 65 63 65 63
Emissions of nitrogen oxides NO
x
mg/kWh
Not applicable
Rated air ow rate Outdoor unit — m³/h 2070 1700 2070 1700 2070 2070 2070 2070
Declared load prole - - L L - - L L
Daily electricity consumption Q
elec kWh - - 4.000 4.000 - - 4.000 4.000
Water heating energy efciency η
wh % - - 120 120 - - 120 120
Daily fuel consumption Q
fuel kWh Not applicable
Contact details
FUJITSU GENERAL (EURO) GmbH
Werftstraße 20, D-40549 Düsseldorf, F. R. Germany
*1 : Optional electrical back up heater consumption is taken into account in the performance calculation.
*2 : For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating
P
designh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup (Tj).
*3 : If Cdh is not determined by measurement then the default degradation coefcient is Cdh = 0.9.