- (OU01 - 10) -
Outdoor unit / Single phase
OUTDOOR UNIT
WO
A060-100LF
OUTDOOR UNIT
WO
A060-100LF
ELECTRICAL SPECIFICATIONS2-5.
Model name (Outdoor unit) WO
A060LFCA WO
A080LFCA WO
A100LFTA
Available voltage range V 198-264
Power supply
Voltage V 230
Frequency Hz 50
*1) Max. operating current Heating
A
12.5 17.5 18.5
*2) Wiring spec.
Main fuse (Circuit breaker)
Current
20 25
Power cable mm² 3.5-4.0
Wiring connections
For power supply
*3) Quantity
3
For connection with
indoor
4
*1) The maximum current is the total current of indoor unit and outdoor unit.
*2) Wiring spec. :
Selected sample
(Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
*3) Included earth wiring.