AA-50
C1-3
4. Self test
1. Tune on the power. (Scanning starts.)
2. Press the TEST switch. (“TEST” LED lights.)
*If problem, the “frequency” LEDs light in order.
2187.5 4207.5 6312 16804.5 REMOTE
(Note)
Lighting Lighting Lighting Lighting Lighting
*If error, Frequency indication LEDs blink. To restart scanning, press any key.
(RCVR board or OSC board is suspected to be faulty)
3. The self test stops automatically and scanning restarts.
(“TEST” LED goes off.)
Note)
The “REMOTE” LED blinks when the AA-50 and DSC-5 (DSC-6) do exchange data.
Cause: DSC turned off, cable between AA-50 and DSC-5 (DSC-6) loosened or
Disconnected, or wrong DSC system settings
DSC-5: [Remote-E] setting ---“OFF” and “TERM”,
DSC-6: [Type] setting ------ OFF”.
To restart scanning, press any key.