IB-582
K2-4
2. Erasing password
If someone sets Supervisor Password and forgot it, AMI BIOS setup program cannot run.
(Supervisor Password setting is unnecessary for IB-582.) In this case, clearing CMOS setup must
be carried out. To do so;
Note; After clearing CMOS setup, BIOS setup must be made.
1. Turn off the unit.
2. Change jumper setting JP31 from #2-#3 to #3-#4.
3. Wait for 5 seconds.
4. Change jumper setting JP31 from #3-#4 to #2-#3.
5. Turn on the unit while pressing and holding down [DEL] key.
6. Release [DEL] key when the following message comes on.
CMOS Checksum Bad
RUN SETUP
Press F1 to Resume
7. Press [F1] key to call AMI BIOS setup menu.
8. Referring to 3. BIOS default, change settings on the following setup menus.
- Standard CMOS Setup
- Advanced COMS Setup
- Advanced Chipset Setup
- Power Management Setup
- Peripheral Setup
9. Select “Save Settings and Exit” in the AMI BIOS setup menu.