DP-6
D2-2
2. Settings list
Function Item Default Setting Note
F3:Operate 6:Manual Reception AUTO
AUTO
5:Answerback Code Entry
Terminal
Ver20 and
after
MMSI+CS(4
digit) +X
Password: ANSWER CODE
(Caps Lock)
6:Group ID Entry (4/5 digit)
7:Group ID Entry (9 digit)
8:Select ID Entry (4/5 digit)
X1 –X5
F5:Station
9:Select ID Entry (9 digit)
MMSI
Password: ID CODE
(Caps Lock)
*Slave Delay 5 msec
5 msec
*BK Timing Pre tone 10 msec
10 msec
*Post Tone 0 msec
0 msec
*Mute Timing Pre BK 0 msec
0 msec
*Post BK 0 msec
0 msec
*Modem Output Level 0 dBm
0 dBm
Password: DP6
(Caps Lock)
Note) Timing depends on the
type of the transceiver unit
connected. See to “Reference”.
MIF Tune OFF OFF
Freeze OFF OFF
AGC OFF ON or OFF
FS-1562:OFF,
FS-5000:ON or OFF
Emission ON ON
TX/RX MSG Save OFF ON or OFF
Edit Before sending OFF On or OFF
Time System UTC UTC
Time & Date ---
ZDA (Terminal Ver 17 and after)
Note) When NMEA data is not
connected, entry by manual.
F6:System
Display Mode Normal Normal
Language Normal Normal
Fn+F1
Printer PP-510 PP-510
Password: DP6
(Caps Lock)
*: Password is needed for change of these setting.
Reference)
Timing values depend on the transceiver connected.
Setting of timing
F6:System
Timing (m sec)
FS-1562
FS-5000
FS-8000
FS-1503
FS-1502
FS-1552
RC-258
RC-508
RC-808
Slave Delay 5 5 5 50 5
BK Timing Pre tone 10 10 10 50 5
Post Tone 0 0 0 10 0
Mute Timing Pre BK 0 0 0 0 0
Post BK 0 0 0 0 0
DP-6 F6:System
MIF AGC
OFF ON or OFF OFF OFF OFF
Remarks
RT :System
settings
9906: 10msec
9982:1
(9913:10msec)
(9917:BK ON)
9910:10 msec
Tx delay time
Default: