1. INITIAL SETTING AND ADJUSTMENT
1-37
1.5 [CCRS] Menu
1.5.1 How to select the [Data Source]
1. Access the [Common Installation Setting] menu and click [CCRS] on the tab bar.
2. Click the [Position] directly item below [Data Source Setting] on the menu bar.
3. Select the data source in order of priority from the [Data Source] pull-down list.
The Equipment IDs checked at [Installation Parameters] menu are shown on the
pull-down list.
When entering the data source, the [Formatter] is automatically entered.
Note: When more than two [Data Source] and [Formatter] are entered, the top-
most entry has the highest priority.
4. Set [Time], [Depth(Bow)], [Depth(Midship)], [Depth(Stern)], [Heading], [Rudder],
[Wind Speed/Direction], [STW(absolute)] (speed through water), [STW(position)]
(speed through ground), [COG/SOG], [Heading Magnetic], [Water Temperature],
[Current], and [Rate of Turn] in a similar manner.
Note: For the processor unit of the Chart Radar, the default data sources are as
follows:
5. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
Item Data Source Remarks
Position GPS001
Time GPS001
Depth(Bow) -----
Depth(Midship) -----
Depth(Stern) -----
Heading GYO001
Rudder -----
Wind Speed/Direction -----
STW(absolute) LOG001 Speed through water
STW(position) LOG001 Speed through ground
COG/SOG GPS001
Heading Magnetic -----
Water Temperature -----
Current -----
Rate of Turn -----
Transmission Group Setting See subsection 1.5.2.
*
*: Position, Heading, STW, COG/SOG, Rate of Turn: Keep the default
setting (3000). For other than the above settings, set “30000” (30 sec.).