1. INITIAL SETTING AND ADJUSTMENT
1-30
13. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
1.4.5 Antenna unit configuration
Do the procedure here to set the antenna unit.
1. Click [Radar Sensor] on the menu bar.
2. Confirm that the Equipment ID checked at the [Own Ship Setting] menu (see
section 1.3) is activated.
3. Click the [Details] button to show the [Details Setting] window.
4. Set the appropriate antenna position from the [Antenna Position] pull-down list.
The interswitch function requires correct input of the antenna position.
5. Click the [OK] button.
6. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
[Details] • [Sensor Type No.]: Enter the sensor
type.
• [Data Name]: Enter the appropriate
data name.
• [Calibration Active]: Check the check
box to display the analog input data
on the conning display and show the
lower columns.
• [Calibration Point1(2)]: Enter input
voltage (or current).
• [Calibration Point Value1(2)]: Enter
the value to show on the conning display. In the example above, the
conning display shows “0” for 0V; “120” for shown for 10V.
Note: For input current, enter the value in ampere units (A).
Item Remarks
Select the appropriate
position.