Scroll to Phone Number and press
OK
.
Press
#
to clear the current value.
Enter 0852525 and press
OK
.
Scroll to Account Code and press
OK
.
Press
#
to clear the current value.
Enter 112233 and press OK.
Scroll to Protocol>SIA and press OK.
6.4 Programming the wireless modules
6.4.1 Defaulting the wireless modules
You must default each module before you start programming it. For more information on
the DIP switch settings on the receiver, see the Installation Manual.
1. Navigate with the µ¶ keys to RF Receivers and press OK.
2. Select the relevant module bus ID and press
OK
. In this case select RF Receiver 32
and press OK.
3. Select Default Settings and press OK.
4. A confirmation message is displayed. Press OK to accept the default settings.
5. The keypad sounder beeps once to confirm the reset.
6.4.2 Programming the wireless detectors
1. Navigate with the µ¶ keys to RF Receivers and press OK.
2. Select the relevant module bus ID and press
OK
. In this case select RF Receiver 32
and press OK.
3. Scroll to Start Zone and press OK.
4. Enter the starting zone of the receiver. In this case, enter zone 9 to set zone 9 as the
starting zone for receiver 32.
5. Scroll to Learn-in Mode and press OK.
6. To learn-in more than one device, scroll to Sequential Programming, select Yes and
press
OK
.
7. Scroll to Start Learning and press OK.
8. Enter the zone number to start with. In this case, enter 9 to program the detectors in
zones 9 and 10 and press
OK
.
9. Tamper the different detectors in sequence.
In this case, tamper the door/window sensor burglary zone. A ding-dong
confirms that the detector in zone 9 has been learned in.
Tamper the PIR detector. A ding-dong confirms that the detector in zone 10 has
been learned in.
10. Press
##
to leave the programming mode. The OK to Exit prompt is displayed. The
system now functions as a normal alarm system. See the CS5500 LCD Keypad User
Manual for information on arming and disarming the system.