7
II. UNDERSTANDING THE LIGHTS
Armed Light
The
armed light
is “on” when the system is armed. The
armed light
is “off” when it is disarmed. The
armed light
will flash when there
has been an alarm during the previous arm cycle.
Bypass Light
The
bypass light
is “on” when any zone in this keypad’s partition
is bypassed. If the
bypass light
is “off”, no zones are bypassed.
Cancel Light
The
cancel light
will flash during an abort delay time. Entering a
code followed by
CANCEL
during or after an alarm report to the
central station will cause the
cancel light
to come on. It will stay on
until the central station has received the cancel report.
NOTE:
The cancel feature must be enabled.
(See "Cancel/Abort
Feature" on page 11.)
Chime Light
The c
hime light
is “on” when the chime feature is “on”; “off”
otherwise.
Exit Light
The
exit light
is “on” during the exit delay. Please note that the light
will flash during the last 10 seconds of the exit delay as a warning
that the time is running out. (The user may want to disarm the
system if the
exit light
is flashing in order to prevent an alarm. The
user may then re-arm the system and exit before the delay
expires.)
Fire Light
A steady
fire light
means a fire zone has been faulted. A rapidly
flashing
fire light
means that a fire zone is in a trouble condition.
Power Light
The
power light
is on if the primary power is on. The
power light
will flash if the system has a low battery condition.
Ready Light
The
ready light
is “on” when the system is ready to arm and
“flashes” if ready to force arm. The
ready light
is “off” when the
system is not ready to arm because of a zone(s) being faulted.
Stay Light
The
stay light
is illuminated when all interior zones are bypassed.
Instant Message
The LCD display will read “Instant“ when the entry/exit door(s)
have no delay. (See “Arming System in Stay Mode”, page 9.) The
doors can be changed from instant to delay (toggled) by pressing
STAY