EasyManuals Logo
Home>GE>Refrigerator>PFE29PS

GE PFE29PS User Manual

GE PFE29PS
91 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
– 41 –
Ambient Thermistor
The ambient thermistor is located inside the hinge
cover on the top of the cabinet The thermistor is
used to set the duty time of the sweat heaters
and adjust the cooling system based on room
temperature.
To replace the ambient thermistor:
1. Place the hinge cover in the service position.
(See Hinge Cover.)
2. Pull the thermistor out from the retaining clips.
Silicone Grease
3. Place the replacement thermistor next to the
original thermistor.
4. Cut the wiring at a location that will match the
original length when the replacement thermistor
is spliced to it.
5. Use plastic bell connectors (Part # WR01X10466).
Fill each connector with silicone grease then
splice a new thermistor into the harness as
shown in the illustration.
Note: Service kit supplied with heat seal connectors.
Thermistor
Clips
Wire Harness
RJ45 Connection Port
Humidity Sensor
A wire harness is connected to the board. The board
is attached to the hinge cover with a Phillips-head
screw.
Zigbee™ Board
Zigbee Board is a wireless communication module
used for an external energy management network.
The Zigbee™ board is located on the top of the
cabinet in the hinge cover. It contains the sensor
that monitors the humidity level of the room and
the RJ45 connection port for energy management
communications.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE PFE29PS and is the answer not in the manual?

GE PFE29PS Specifications

General IconGeneral
BrandGE
ModelPFE29PS
CategoryRefrigerator
LanguageEnglish

Related product manuals