– 51 –
Failure Codes
The oven may stop operating but not give an F code on the display immediately. F codes are stored in
nonvolatile EEPROM memory until the same fault occurs twice consecutively. After that, the F code will
be displayed. F codes can be recalled by pressing together TIMER, CLOCK, MIN DOWN or 9. While F
codes are displayed, pressing MIN UP or 8 and HR DOWN or 6 together will clear them. A fault must
exist continuously for 5 minutes before an F code is recorded (F2 and F8 are sooner).
Diagnostics and Service Information
FAILURE
CODE MEANING CORRECTION
Shorted OFF key
-F0-
Determine if problem is with key panel or control by
disconnecting ribbon cable and measuring flat cable
pins 13 to 14. Should be open. Should be 100–150
ohms while pressing OFF key.
Over temperature
1. Inside oven cavity as
measured by sensor
over 650°F unlatched
or 915°F latched or
2. Cooling fan stalls while
oven above 650°F—
open thermal switch in
yellow leads
Welded relay contacts
Cooling fan stalled or blocked
Airflow to rear of unit
High resistance in oven sensor leads/connectors
(especially at sensor in rear)
-F3-
Open oven sensor (under
950 ohms)
Disconnect power. Disconnect sensor harness from
control. Measure sensor resistance (white leads) to
be ~1080 ohms at room temperature with 2 ohms
per degree change.
Look for damaged harness terminals if not a bad
sensor.
Shorted oven sensor
(over 2900 ohms)
Disconnect power. Disconnect sensor harness from
control. Measure sensor resistance (white leads) to
be ~1080 ohms at room temperature with 2 ohms
per degree change.
Separate sensor from harness to determine fault.
Shorted matrix or START
key
Determine if problem is with key panel or control by
disconnecting ribbon cable and measuring flat cable
using pinout chart. Allow up to 1000 ohms when
pressing a key.
-F2-
-F4-
-F7-
EEPROM data shift failure
If repeated, replace control.
Cooling fan or airflow to control area.
Cooling fan stalls while
above 650°F; open
thermal switch in yellow
leads
-F8-
-F9-
Loss of latch motor safety
circuit
Replace control.
-FF-

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Profile J2S968 SERIES and is the answer not in the manual?

GE Profile J2S968 SERIES Specifications

General IconGeneral
BrandGE
ModelProfile J2S968 SERIES
CategoryRanges
LanguageEnglish

Related product manuals