Chapter 3 Environment & Installation
3.1 Environment
Installation environment has a direct effect on the correct operation and the life expectancy of the
inverter, Install the inverter in an environment complying with the following conditions:
IP20
Operating
temperature
-10~40°C (size 1) -10~50°C (other sizes)
If several inverters are installed in the same control panel, ensure
adequate spacing and provide the necessary cooling and ventilation for
successful operation.
-20~60°C
Max 95% (without condensation)
Altitude
:
It is required to reduce 2% of inverter rated current at each additional
100m. The maximum altitude is 3000m
See ch. 3.2.3 Derating curves.
Shock
2G (19.6m/s²) for 57~150Hz and below.
0.3mm for 10~57Hz (According to IEC60068-2-6 standard)
Installation site
Install in an environment that will not have an adverse effect on the operation of the unit
and ensure that there is no exposure to areas such as that listed below:
Direct sunlight, Rain or moisture
Dust, lint fibres, small metal filings and corrosive liquid and gas
Electromagnetic interference from sources such as welding equipment
Radioactive and flammable materials
Excessive vibration from machines such as stamping, punching machines
Add vibration-proof pads if necessary