3-22
Additional protective
functions
Heatsink over temperature protection, Auto carrier frequency
reduction with temperature rise, Protection of reverse
operation, Auto restart attempts setting, Parameter lock
Environment
Specification
Protection degree
IP20
Operating temperature
-10~ +40°C (size 1), -10~+50°C (all other sizes)
Storage temperature
-20~60°C
Humidity
Under 95%RH ( no condensation)
Altitude
1000 meters or lower
Vibration
Under 20Hz, 1G(9.8m/s²); 20
50Hz 0.6G(5.88m/s²)
Communication Function
Built in: RS-485 with Modbus RTU / ASCII (standard RJ45
connection), BACnet
Optionals: Profibus, DeviceNet, CANopen, TCP/IP
Braking unit
Built-in on 3ph 400V Class and 3ph 200V Class from 3.7kW to
7.5kW
EMC filter
Built-in on F version 1ph 200V Class and 3ph 400V Class
Certification
CE
In compliance with EN61800-3 (CE & RE) and EN61800-5-1
(LVD)
Note: Inverter can get the better grounding effect with grounding kit.
RoHS
Conformity to RoHS directive
cULus
UL508C