Page #39 background image
SECTION 3.2
410cc TROUBLESHOOTING FLOW CHARTS
Page 37
ENGINE TROUBLESHOOTING
PART 3
RECHARGE OR REPLACE BATTERY
– CLEAN, REPAIR OR REPLACE
BAD CABLE(S)
BAD
REPLACE
BAD
GOOD
NO VOLTAGE
MEASURED
BAD
12 VDC
MEASURED
REPLACE STARTER
MOTOR IF DEFECTIVE
GOOD
CHECK FOR MECHANICAL BINDING
OF THE ENGINE OR ROTOR
Problem 20 – Engine Will Not Crank
TEST 21 – CHECK
BATTERY
& CABLES
TEST 23 – CHECK
START-RUN-STOP
SWITCH
TEST 25 – CHECK
STARTER MOTOR
TEST 22 – CHECK
VOLTAGE AT
STARTER
CONTACTOR
NOTHING
FOUND
FIX BAD COMPONENT
BAD
VISUALLY INSPECT FOR OBSTRUCTIONS
THAT WOULD CAUSE BINDING OF THE
RECOIL ONCE INSTALLED
AN INTERNAL ENGINE FAILURE HAS OCCURED.
POSSIBLE FAILURE COULD BE THE RESULT OF
A COMPRESSION RELEASE FAILURE. CONSULT
ENGINE SERVICE MANUAL P/N 0C1103A FOR
FURTHER ENGINE SERVICE INFORMATION.
VISUALLY INSPECT EXTERNAL
COMPONENTS FOR A FAILURE
THAT WOULD CAUSE THE
ENGINE TO BE SIEZED
REPLACE
BAD
BAD
GOOD GOOD
Problem 21 – Recoil Cord Will Not Pull (If So Equipped)
TEST 50 –
TEST ENGINE
FUNCTION
TEST 49 – TEST
RECOIL
FUNCTION

Table of Contents

Other manuals for Generac Power Systems GP6500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems GP6500 and is the answer not in the manual?

Generac Power Systems GP6500 Specifications

General IconGeneral
BrandGenerac Power Systems
ModelGP6500
CategoryPortable Generator
LanguageEnglish

Related product manuals