8.
Click Apply.
6.4.4 Congure Arming Schedule
Steps
1.
Click Arming Schedule.
2.
Choose one day of a week and set the me segment. Up to eight me periods can be set within
each day.
Note
Time periods shall not be repeated or overlapped.
Figure 6-25 Set Arming Schedule
3.
Click Apply.
6.4.5
Congure Alarm Linkage Acon
Congure Alarm Pop-up Window
When an alarm is triggered, the local monitor displays in full screen the video image from the
alarming channel
congured for full screen monitoring. And when the alarm is triggered
simultaneously in several channels, you must congure the auto-switch dwell me.
Steps
1.
Go to Conguraon → System → Live View → General .
2.
Set the event output and dwell
me.
Alarm Pop-up Output
Select the output to show event video.
Alarm Pop-up Delay
Digital Video Recorder User Manual