User Manual of Digital Video Recorder
61
4.2.5 Customizing Patterns
Purpose:
Patterns can be set by recording the movement of the PTZ. You can call the pattern to make the PTZ movement
according to the predefined path.
Steps:
1. Enter the PTZ Control interface.
Menu > Camera > PTZ
Figure 4. 8 PTZ Settings
2. Choose pattern number in the dropdown list.
3. Click the Start button and click corresponding buttons in the control panel to move the PTZ camera, and
click the Stop button to stop it.
The movement of the PTZ is recorded as the pattern.
4.2.6 Calling Patterns
Purpose:
Follow the procedure to move the PTZ camera according to the predefined patterns.
Steps:
1. Click the button PTZ in the lower-right corner of the PTZ setting interface;
Or press the PTZ button on the front panel or click the PTZ Control icon in the quick setting bar, or
select the PTZ option in the right-click menu to show the PTZ control panel.
2. Click the button to show the general settings of the PTZ control.

Table of Contents

Other manuals for HIKVISION DS-7204HGHI-SH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-7204HGHI-SH and is the answer not in the manual?

HIKVISION DS-7204HGHI-SH Specifications

General IconGeneral
Product colorBlack
Channels quantity4 channels
Total storage capacity1000 GB
Video compression formatsH.264
Playback resolutions supported1920 x 1080, 1280 x 1024, 1280 x 720, 1024 x 768
Audio input1
BNC input ports4
USB 2.0 ports quantity2
Ethernet interface typeFast Ethernet
Supported network protocolsTCP/IP, PPPoE, DHCP, DNS, DDNS, NTP, SADP, SMTP, SNMP, NFS, iSCSI, UPnP, HTTPS
HDD interfaceSerial ATA
Power requirements12V DC
Power consumption (typical)15 W
Operating temperature (T-T)-10 - 55 °C
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Dimensions (WxDxH)315 x 242 x 45 mm