EasyManuals Logo
Home>HIKVISION>Network Hardware>HWN-4108MH-8P

HIKVISION HWN-4108MH-8P User Manual

HIKVISION HWN-4108MH-8P
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
Before You Start
Enable the UPnP™ funcon of your router if UPnP™ is required. When the device network working
mode is mul-address, the default device route should be on the same network segment as the
LAN IP address of the router.
Steps
1.
Conguraon → Network → General → NAT .
2.
Check Enable.
3.
Select Mapping Type as Manual or Auto
Auto The port mapping items are read-only, and the external ports are set by the router
automacally. You can click Refresh to get the latest status of the port mapping.
Manual Select an external port type. Click to edit External Port. You can use the default
external port No., or change it according to actual requirements. External Port
indicates the port No. for port mapping in the router.
The value of the RTSP port No. should be 554 or between 1024 and 65535, while
the value of the other ports should be between 1 and 65535 and the value must be
dierent from each other. If mulple devices are congured for the UPnP™ sengs
under the same router, the value of the port No. for each device should be unique.
4.
Set the virtual server of your router, including internal source port, external source port, etc. The
virtual server parameters shall be corresponding with your device port.
6.2.4 Ports (More
Sengs)
Set dierent port types to enable relevant funcons as your desire.
Go to Conguraon → Network → General → More Sengs .
Alarm Host IP/Port
The device will send the alarm event or excepon message to the alarm host when an alarm is
triggered. The remote alarm host must have the client management system (CMS)
soware
installed.
Alarm Host IP refers to the IP address of the remote PC on which the CMS
soware (e.g.,
iVMS-4200) is installed, and the Alarm Host Port (7200 by default) must be the same as the
alarm monitoring port
congured in the soware.
Server Port
For remote client soware access. Ranges from 2000 to 65535. The default value is 8000.
HTTP Port
For remote web browser access. The default value is 80.
Mulcast IP
Mulcast can be congured to enable live view for cameras that exceed the maximum number
allowed through network. A mulcast IP address covers Class-D IP ranging from 224.0.0.0 to
Network Video Recorder User Manual
46

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION HWN-4108MH-8P and is the answer not in the manual?

HIKVISION HWN-4108MH-8P Specifications

General IconGeneral
BrandHIKVISION
ModelHWN-4108MH-8P
CategoryNetwork Hardware
LanguageEnglish

Related product manuals