08-9
Emptying the therme:
• Disconnect the electricity supply to the water
pump on the main switch or transformer.
• Open all faucets.
• Setallpre-mixingvalvesto"warm"ifneces-
sary.
• Open the runoff valve (4).
• Check to see if water runs out.
• Close the runoff valve (4) after emptying (if
necessary, blow the line out).
Electric operation:
• Set the switch on the control panel (3) to the
"on" position. When the light comes on, the
unit is operating. Regulate the temperature to
55° C, using the thermostat.
• Power consumption: 300 W.
Rules for the therme:
• Shut off the device when the camper is not in
use.
• Empty the therme at the risk of frost. Frozen
water can cause the therme to burst!
• No recoil valve may be built into the cold
water faucet (1) between the therme and the
immersion pump.
• A depressuriser must be used if the pump is
connected to a central water supply, or on
stronger pumps. The pressure in the therme
maynotexceed1.2bar.Inaddition,asafety
valve or runoff valve (1) must be used in the
cold water tap.
• We recommend that you do not use the water
from the therme as drinking water.
Never operate the therme electrically
when it is empty.
WARNING:
Theblockcircuitdiagramonlyreectsthefunc-
tion.Duetothevariousoorplans,individual
modicationsarepossible.
2
1
3
4
Plan for warm water supply