09-5
9.3 Heating element
Heating element S 5002 and
S 3002
- Above: S 5002 (models 560 to 750)
- Below: S 3002 (models 400 to 540)
Place of installation:
- in the closet or the corner of the ue
Before rst use:
• Several air outlet nozzles have been built
into the camper. Pipes lead the hot air to the
air outlet nozzles. Turn the nozzles so that
the hot air is expelled where you want it.
• Before the rst ignition, ensure that the bat-
teries in the automatic ignitor are working
properly.
Operation:
• Open the bottle valve and the quick-close
valve in the gas line.
• Turn the operation handle (1) to the thermo-
stat position 1-10.
• Press the operation handle (1) down until
it locks. The ignition is automatic from this
position, until the ame burns. The ignition
spark is audible. The control light on the
automatic ignitor (2) blinks during ignition.
• Hold the operation handle in for up to 10
seconds, so that the ignition fuse kicks in.
• If the gas line is lled with air, it can take up
to a minute until the gas is ready to burn.
Hold the operation lever (1) in during this
period, until the ame burns.
Never re-ignite before two minutes
have passed. Otherwise, there
is a danger of deagration! This
also applies when the ame on an
already operational heating element
extinguishes and is re-ignited.
2
1
Heating while driving is forbidden.