Rev 7, July/2002 00643I05.TDC Page 2-29
2. Adjust the GAIN knob for a GAIN POT setting between -24.5 and -26.5 (see figure
2-10). An 02 should be displayed in the AZIMUTH COUNT field (see table 2-2).
3. Adjust the TILT SETTING between 5 and 10 UP to increment the PITCH ANGLE
field to 10.0 ± 1.0
°
(adjusting the TILT SETTING between 5 and 10 DOWN will dec-
rement the numbers). Upon reaching the desired setting, quickly adjust the TILT
SETTING to above 10 to lock in the setting. See figure 2-11.
4. Set to 5
°
PITCH DOWN and repeat steps 2 and 3 of this section.
5. Set the tilt table to 0
°
pitch and roll.
6. Proceed to Step O.
O. ROLL GAIN
1. In determining the tilt for the table use the standard rate turn for the aircraft being
aligned.
2. Adjust the GAIN knob for a GAIN POT setting between -21.0 and -23.0 (see figure
2-10). An 03 should be displayed in the AZIMUTH COUNT field (see table 2-2).
3. Adjust the TILT SETTING between 5 and 10 UP to increment the ROLL ANGLE
field to 10.0 ± 1.0
°
(adjusting the TILT SETTING between 5 and 10 DOWN will dec-
rement the numbers). Upon reaching the desired setting, quickly adjust the TILT
SETTING to above 10 to lock in the setting. See figure 2-11.
4. Set to 10
°
roll left. Repeat steps 2 and 3 of this section.
5. Set the tilt table to 0
°
pitch and roll.
6. Proceed to Step R.
P. AHRS ARINC 429 PITCH OFFSET
1. Adjust the GAIN knob for a GAIN POT setting between -10.5 and -12.5 (see figure
2-10). An 06 should be displayed in the AZIMUTH COUNT field (see table 2-2).
2. Check that the tilt table is set for 0
°
pitch.
3. Adjust the TILT SETTING between 5 and 10 UP to increment the PITCH ANGLE
field to 0.0 ± 1.0
°
(adjusting the TILT SETTING between 5 and 10 DOWN will dec-
rement the numbers). Upon reaching 0
°
± 1.0
°
, quickly adjust the TILT SETTING
to above 10 to lock in the setting. See figure 2-11.
4. Set the tilt table to 10
°
pitch up. The value should be 10.0U ± 1.0
°
. If the value is
out of range, repeat Steps 1, 2, and 3 of this section.
5. Set the tilt table to 10
°
pitch down. The value should be 10.0D ± 1.0
°
. If the value
is out of range, repeat Steps 1, 2, 3, and 4 of this section.
6. Set the tilt table to 0
°
pitch. The value should be 0.0 ± 1.0
°
.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell BENDIX/KING RDR 2000 and is the answer not in the manual?

Honeywell BENDIX/KING RDR 2000 Specifications

General IconGeneral
BrandHoneywell
ModelBENDIX/KING RDR 2000
CategoryRadar
LanguageEnglish

Related product manuals