Mechanics of Programming
Interactive Menu Mode Programming (✻56, ✻80, ✻81, ✻83, ✻84, ✻85)
Press
[✻] + interactive mode No. (i.e., ✻56). The keypad will display the first of a series of prompts. A detailed
procedure (with displays of prompts) is provided in later sections of this manual.
✻
56 Enhanced Zone Programming Mode
Interactive menu mode used for programming zone attributes and report codes. Refer to the
✻
56
Enhanced Zone Programming Mode section for procedure.
✻
80 Device Programming Menu Mode
Interactive menu mode for programming Powerline Carrier Devices. Refer to the
✻
80 Device
Programming Menu Mode section for detailed procedure.
✻
81 Zone Lists Menu Mode
Interactive menu mode for programming zone lists for Powerline Carrier Devices. Refer to the
✻
81
Zone List Menu Mode section for detailed procedure.
✻
83 Enhanced Sequential Mode
Interactive menu mode used to enter RF transmitter serial numbers. Refer to the
✻
83 Enhanced
Sequential Mode section for detailed procedure.
✻
84 Assign Zone Voice Descriptors
Interactive menu mode used to assign descriptors to each zone. These descriptors will be announced
whenever the system announces an event involving a zone.
✻
85 Record Custom Voice Descriptors
Interactive menu mode used to record custom descriptors for use with each zone.
✻
96 Initialize Download ID and Subscriber Account Number for Downloading
Entering
✻
96 resets all subscriber account numbers and CSID in preparation for an initial download.
Loading Factory Defaults
If a default table is loaded, any data that has already been programmed into the system will be changed
according to the default table selected!
✻
97 To load the factory defaults, enter ✻97, then press number 1, 2, 3, or 4 to select from default tables
1-4,
or press “0” if you are not selecting a default table. Refer to the Programming Default Tables section of this
manual to view the tables.
Exiting Program Mode
Do not exit Program Mode via *98 if you intend to enter LRR Communication Device Diagnostic Mode.
✻98 Exits program mode and inhibits re-entry into the Expert or Voice Prompt Programming modes using
the Installer Code.
✻99 Exits program mode but allows re-entry into the Expert Program mode using Installer Code (4112) +
800 or into the Voice Prompt Programming mode using Installer Code (4112) + 888.
Note: After exiting program mode (or upon power-up), the system takes up to a minute to reset. To bypass the reset
delay, press [#] + [0].