Lynx Plus Series Installation and Setup Guide
- 20 -
Data Field Descriptions
The following pages list all data fields in this Control (in numerical order). Use the blank programming form
to record the data for this installation. Specific fields include options for programming that are unique to
the LynxSIA Plus version. Note that both keypad LEDs flash while in Programming mode. The LynxSIA
Plus version validates the data entry for the Fields listed below. If data entered is not within valid range,
the control will emit a long beep indicating that entry is rejected and will substitute the default value for the
invalid entry. The default value will be displayed on the keypad, and the control advance to the next field.
Field Name Default Value Valid Range
*34 Exit Delay 60 45-97
*35 Entry Delay 01 30 30-99
*36 Entry Delay 02 30 30-99
*50 Burglary Dial Delay 2 1-3
*57 False Alarm Options 7 0-7
*59 Exit Error Report Code 1 1-F
*64 Test Report Code 10 10-FF
*68 Cancel Report Code 10 10-FF
*69 Recent Closing Report Code 1 1-F
*76 Test Restore Report 10 10-FF
*92 Swinger Shutdown 1 1-2
Note: Entering a number other than the one specified will give unpredictable results.
20
2020
20
INSTALLER
INSTALLER INSTALLER
INSTALLER
CODE
CODECODE
CODE
Installer Code
The Installer Code is used to enter the 4-digit Master Security Code. See "Master Code"
in the System Operation section for procedure.
Note: LynxSIA Plus does not allow duplication of Installer code. If a duplicate code is
entered the entry is rejected and LYNX issues single long beep indicating rejection.
The old installer code remains unchanged.
SELECTIONS
Enter 4 digits (0-9)
21
2121
21
QUICK
QUICK QUICK
QUICK
ARM
ARMARM
ARM
ENABLE
ENABLEENABLE
ENABLE
Quick Arm Enable
If enabled, security code is not required to arm the system. The user simply presses and
holds down the AWAY or STAY key to arm.
SELECTIONS
0 = do not allow quick arm
1 = allow quick arm
22
22 22
22
K
KK
KEY
EYEY
EYP
PP
PA
AA
AD
DD
D
B
BB
BACKLI
ACKLIACKLI
ACKLIGHT
GHTGHT
GHT
Keypad Backlight Timeout
This option allows the choice of either always backlighting the keypad or turning the
backlighting off after 10 seconds of keypad inactivity.
SELECTIONS
0 = no timeout; always backlight keys
1 = turn backlighting off after inactivity
2
22
23
33
3
FORCED
FORCED FORCED
FORCED
BYPASS
BYPASS BYPASS
BYPASS
Forced Bypass
All zones bypassed by this function will be displayed after the bypass is initiated.
UL installations: must be 0 (no forced bypass)
SELECTIONS
0 = no forced bypass
1 = provide automatic bypass of all open (faulted) zones
24
2424
24
RF
RF RF
RF
HOUSE
HOUSEHOUSE
HOUSE
ID
ID ID
ID
CODE
CODE CODE
CODE
RF House ID Code
The House ID identifies receivers and wireless keypads. If a 5804BD/5804BDV
Transmitter is to be used, a House ID Code MUST be entered, and the keypad should
be set to the same ID.
SELECTIONS
00 = disable all wireless keypad usage
01-31 = House ID

Table of Contents

Other manuals for Honeywell Lynx Plus Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Lynx Plus Series and is the answer not in the manual?

Honeywell Lynx Plus Series Specifications

General IconGeneral
BrandHoneywell
ModelLynx Plus Series
CategorySecurity System
LanguageEnglish

Related product manuals