Lynx Plus Series Installation and Setup Guide
- 21 -
Data Field Descriptions
25
2525
25
X10
X10X10
X10
HOUSE
HOUSE HOUSE
HOUSE
CODE
CODE CODE
CODE
Powerline Carrier Device (X10) House ID
Powerline Carrier Devices require a House ID. This field identifies this House ID to the
Control. The Powerline Carrier Devices are programmed in field ✻80.
SELECTIONS
0 = A 3 = D 6 = G 9 = J # + 12 = M # + 15 = P
1 = B 4 = E 7 = H # + 10 = K # + 13 = N
2 = C 5 = F 8 = I # + 11 = L # + 14 = O
26
2626
26
CHIME
CHIME CHIME
CHIME
BY
BY BY
BY
ZONE
ZONEZONE
ZONE
Chime by Zone
This option allows the installer to define the specific zones intended to chime when
faulted while the system is in Chime mode. If enabled, these zones are defined in zone
list 3 (see ✻81 Zone List Menu Mode).
SELECTIONS
0 = no (chimes on fault of any entry/exit or perimeter zone when Chime mode is activated)
1 = yes (chimes on fault of those zones assigned to Zone List 3 when Chime mode on)
27
2727
27
CLOCK
CLOCK CLOCK
CLOCK
DISPLAY
DISPLAYDISPLAY
DISPLAY
Real Time Clock Display
Refer to the User’s Manual for setting the clock time and date.
SELECTIONS
0 = do not display the time
1 = display the time
29
2929
29
DST
DST DST
DST
MNTH
MNTH MNTH
MNTH
STR
STRSTR
STR/END
ENDEND
END
Daylight Savings Time Start/End Month
Enter # + 10 for 10, # + 11 for 11, and # + 12 for 12.
SELECTIONS
0 = do not display the time
1 = display the time
30
3030
30
DST
DST DST
DST
WEEK
WEEK WEEK
WEEK
STR
STRSTR
STR/END
ENDEND
END
Daylight Savings Time Start/End Month
Enter the appropriate start and end weekend of the month.
SELECTIONS
0 = disable 4 = fourth weekend
1 = first weekend of month 5 = last weekend
2 = second weekend 6 = next to last
3 = third weekend 7 = 3rd from last
31
3131
31
SINGLE
SINGLE SINGLE
SINGLE
ALARM
ALARM ALARM
ALARM
SND
SNDSND
SND
Single Alarm sounding Per Zone (per armed period)
This field applies only to burglary zones (zone response types 1-5, 10). It applies only to
the bell and does not affect keypad sounds.
UL installations: must be 0 (no limit)
Lynx Plus SELECTIONS
0 = no limit on alarm sounding per zone
1 = limit alarm sounding to once per arming period for a given zone
LynxSIA Plus SELECTIONS
0 = alarm sounding per zone will be the same as Swinger Shutdown set in field ✻92
1 = limit alarm sounding to once per arming period for a given zone
32
3232
32
FIRE
FIREFIRE
FIRE
SND
SND SND
SND
T
TT
TIMEOUT
IMEOUTIMEOUT
IMEOUT
Sounder Timeout
This Control complies with NFPA requirements for temporal pulse sounding of fire and
carbon monoxide (CO) notification appliances. Temporal pulse sounding for a fire alarm
consists of the following:
3 pulses – pause – 3 pulses – pause – 3 pulses. . .
Temporal pulse sounding for a CO alarm consists of the following:
4 pulses – pause – 4 pulses – pause – 4 pulses –pause. . .
SELECTIONS
0 = yes, sounder timeout after time programmed in field ✻33
1 = no sounder timeout; continue sounding until manually turned off