Lynx Plus Series Installation and Setup Guide
- 69 -
Programming Default Tables
LynxSIA Plus Control Defaults
(boldface indicates defaults that differ between tables)
Function Table 1 Table 2 Table 3 Table 4
*20 Installer code 4112 4112 4112 4112
*21 Quick arm enable 1 1 1 1
*22 Keypad backlight timeout 0 0 0 0
*23 Forced bypass 0 0 0 0
*24 RF house ID code 0,0 0,0 0,0 0,0
*25 Powerline carrier device house code 0 0 0 0
*26 Chime-by-zone 0 0 0 0
*27 Real-time clock display 1 1 1 1
*29 Daylight saving time start/end month 3,11 3,11 3,11 3,11
*30 Daylight saving time start/end weekend 2,1 2,1 2,1 2,1
*31 Single alarm sounding per zone 0 0 0 0
*32 Fire sounder timeout 0 0 0 0
*33 Alarm bell timeout 1 1 1 1
*34 Exit delay 6,0 6,0 6,0 7,0
*35 Entry delay 1 (zone type 01) 3,0 3,0 3,0 3,0
*36 Entry delay 2 (zone type 02) 3,0 3,0 3,0 3,0
*38 Confirmation of arming ding 0 0 0 0
*39 Cross zone timer 0 0 0 0
*40 PABX access code/Call waiting disable --- --- --- ---
*41 Primary phone number --- --- --- ---
*42 Secondary phone number --- --- --- ---
*43 Primary subscriber account number 15,15,15,15 15,15,15,15 15,15,15,15 15,15,15,15
*44 Secondary subscriber account number 15,15,15,15 15,15,15,15 15,15,15,15 15,15,15,15
*46 “Follow Me Reminder” Phone Number --- --- --- ---
*47 Phone system select 5 5 5 5
*48 Report format for primary/secondary 7,7 7,7 7,7 7,7
*49 Split/dual reporting 0 0 0 9
*50 Burglary abort window 2 2 2 2
*51 Periodic test report 0 3 0 0
*52 First test report offset 2 2 2 2
*53 Sescoa/radionics select 0 0 0 0
*54 Lack of usage notification 0 0 0 0
*55 Reporting channels 0 0 0 0
*56 Enhanced zone programming See *56 table See *56 table See *56 table See *56 table
*57 False alarm options 7 7 7 7
*58 RF jam detection 0 0 0 0
*59 Exit error report code 1 1 1 1
*60 Trouble report code 1,0 1,0 1,0 1,0
*61 Bypass report code 0,0 0,0 0,0 0,0
*62 AC loss report code 0,0 0,0 0,0 0,0
*63 Low battery Report code 1,0 1,0 1,0 1,0
*64 Test report code 1,0 1,0 1,0 1,0
*65 Open report code 0 0 0 0
*66 Arm away/stay report code 0,0 0,0 0,0 0,0
*67 RF transmitter low battery report code 1,0 1,0 1,0 1,0
*68 Cancel report code 1,0 1,0 1,0 1,0
*69 Recent close report code 1 1 1 1
*70 Alarm restore codes 1 1 1 1
*71 Trouble restore report code 1,0 1,0 1,0 1,0
*72 Bypass restore report code 0,0 0,0 0,0 0,0
*73 AC restore report code 0,0 0,0 0,0 0,0
*74 Low battery restore report code 1,0 1,0 1,0 1,0
*75 RF transmitter low battery restore report code 1,0 1,0 1,0 1,0
*76 Test restore report code 1,0 1,0 1,0 1,0
*77 Dynamic Signaling Delay/ Dynamic Signaling Priority 0,0 0,0 0,0 0,0
*78 Programmable Tone Generation Time 0,0 0,0 0,0 0,0
*80 Powerline Carrier Devices See *80 table See *80 table --- See *80 table
*81 Zone lists for devices See *81 table See *81 table See *81 table See *81 table

Table of Contents

Other manuals for Honeywell Lynx Plus Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Lynx Plus Series and is the answer not in the manual?

Honeywell Lynx Plus Series Specifications

General IconGeneral
BrandHoneywell
ModelLynx Plus Series
CategorySecurity System
LanguageEnglish

Related product manuals