4.6 Troubleshooting During Console Power-up
If your server management keeps looping on trying to form the group, then you
need to check your NAT box carrier lights for port connections. Next check all
drawers within the cabinet (I/O and 2P drawers) to be certain they have unique
identifiers.
Issuing the Set Membership command should stop the broadcast message and enable server
management to create a new group ID. If your system keeps looping, your drawers may have
faulty connections to the system NAT box. Each SM LAN connection should show two
active LEDs.
If looping persists, check the ID numbers on the OCP of each drawer. Every drawer within
any cabinet must have a unique ID. Your 2P drawers should have Ids 0, 1, 2, and 3,
respectively, working from bottom to top.
Configure and Troubleshoot 4-11