Table 6-1 cfggen Commands (continued)
DescriptionCommands
Turn ON and OFF a drive's Identify LED.
LOCATE
Display current volume status information.
STATUS
Bring a hard disk offline (in IM/IME volumes).
SETOFFLINE
Bring a hard disk online.
SETONLINE
The <parameters> are command specific values.
To obtain command help, you can use cfggen <controller #> <command>.
Examples
Example 6-1 cfggen list Command
SSTK-v.2.6-4# cfggen list
LSI Logic IR Configuration Utility 2.00.14
Adapter Vendor Device Segment
SubSys SubSys Index Type ID ID ID Bus Device Func
Ven ID Dev ID
----- --------- ------ ------ ------- --- ------ ---- ------ ------
0 SAS1068 1000h 54h 0000h 02h 01h 00h
103ch 170dh
Example 6-2 cfggen Display Command
SSTK-v.2.6-4# cfggen 0 display
SSTK-v.2.6-4# cfggen 0 display
LSI Logic IR Configuration Utility 2.00.14
Read configuration has been initiated for controller 0
------------------------------------------------------------------------
Controller information
------------------------------------------------------------------------
Controller type : SAS1068
BIOS version : 2.00.14.00
Firmware version : 1.10.01.00
Channel description : 1 Serial Attached SCSI
Initiator ID : 63
Maximum physical devices : 62
Concurrent commands supported : 511
Slot : Unknown
Bus : 2
Device : 1
Function : 0
RAID Support : Yes
------------------------------------------------------------------------
IR Volume information
------------------------------------------------------------------------
------------------------------------------------------------------------
Physical device information
------------------------------------------------------------------------
Initiator at ID #63
Target on ID #1
Device is a Hard disk
Enclosure # : 1
Slot # : 1
Target ID : 1
State : Ready (RDY)
Size (in MB)/(in sectors) : 57231/117210240
Manufacturer : ATA
Model Number : FUJITSU MHT2060B
Firmware Revision : 034E
Serial No : NR0LT5625AJP
Drive Type : SATA
Target on ID #2
48 Utilities Reference