Page #82 background imageLoading...
Page #82 background image
No MSA Storage Information Displayed by ACU
The ACU does not capture configuration information from the Emulex HBA that connects to
MSA storage so no information about the storage device is displayed by the ACU. This is a known
issue with the ACU.
To avoid this issue, configure Emulex boot devices with hplpcfg.
Incorrect Logical Disk Drive Size Displayed
The logical disk size was not specified with the cfggen utility. When executing the command
cfggen 0 auto IM 2000 qsync to create a logical disk with 2000 MB size, the size displayed
after creating the logical disk is 1872 MB rather than 2000 MB. There is a coercion algorithm
applied by cfggen that rounds off the drive sizes that are then be used for size of the logical
volume. Ideally, the MAX option is used to configure a volume with the maximum possible drive
size.
HP recommends that you always use the MAX option. Specifying a size for logical volume is not
supported.
Capturing and Deploying an Image on the Same Server
SSTK was not designed to allow the capture of a Linux image from one disk for deployment to
another disk on the same server. This operation causes a conflict of the UUID or volume group
name of different disks on the same server.
If you have captured image from one disk, sda, to deploy it to another disk, sdb, on the same
server, make sure that the UUID or volume group name are unique to avoid a conflict during
the image deployment process.
SSTK can only deploy an image successfully if the UUID or volume group name has been cleared
prior to deployment.
cfggen Crashes on HP Integrity Virtual Machine
When executing the command, cfggen 0 display, the system may crash and display the
following error:
*** glibc detected *** double free or corruption (fasttop):
0x600000000000f070 ***
The cfggen utility is not supported nor is it tested by LSI in the HP Integrity VM environment;
do not use the cfggen utility in this environment.
hpshowdisk Unknown Device Error
After running ACU, hpshowdisk is not able to show information for some cciss devices and
returns an unknown device error message. This error is the result of an issue in ACU that
deletes data in the /sys/block/ directory that is used by the hpshowdisk command to display
disk device information.
Reload the cciss module using the rmmod cciss and modprobe ccisscommands in order,
or reboot the system.
Invalid MP Version Displayed on sx1000 Servers
The MP version information returned by hpia64info on sx1000 (SD64A and SD32A) servers
is invalid. This issue does not occur on other HP Integrity servers.
You must use the sysrev EFI command to retrieve the correct MP version rather than the
hpia64info command on sx1000 servers.
82 Known Issues

Table of Contents

Other manuals for HP BL860c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP BL860c and is the answer not in the manual?

HP BL860c Specifications

General IconGeneral
BrandHP
ModelBL860c
CategorySoftware
LanguageEnglish

Related product manuals