Table 6-8 Error Codes (continued)
ReasonErrorCode
The Resource Volume owner cannot be changed if it is a
configured logical drive.
Cannot change Resource Volume
Owner
2860
The controller is not redundant or does not support
redundancy settings.
Controller does not support
redundancy settings
2861
The preferred path mode is not a valid preferred path mode
or the controller is not available.
Invalid Preferred Path Mode
2864
The preferred path specified is not a valid chassis-slot for an
available active controller or the controller is not available.
Invalid Preferred Path
2865
Invalid Physical Drive count. A possible reason is that more
disks were requested than available of the current DriveType.
Invalid Physical Drive Count
2876
No suitable Spares available.
No Spares Available
2877
Spares are not supported in RAID0-only Arrays.
Spare Request for RAID0 is
Invalid
2878
Mode is Reconfigure and a controller reset with data loss was
specified.
Reset and Reconfigure combined
Error
2879
Invalid Disk Type specified.
Invalid Drive Type Specified
2880
An internal ACU error has occurred. This error should never
occur. If it does, there is a problem with ACU, and some error
is not being identified properly.
Internal Error
516
efibootmgr
Synopsis
efibootmgr [command]... [option]...
Description
The efibootmgr utility is used from a script file to manage the EFI Boot variables. The
efibootmgr utility is used for creating or destroying the EFI BOOT variables and to update the
BOOT NEXT, BOOT ORDER and TIMEOUT variables.The BOOT ORDER variable defines the boot
entries sequence to be shown in menu. The TIMEOUT variable sets the time-out to select
automatically the boot variables, according to BOOT ORDER. The BOOT NEXT variable sets the
next boot entry to be selected automatically disregarding the BOOT ORDER and TIMEOUT.
Table 6-9 efibootmgr Options
DescriptionOptions
Set bootnum active.
-a | --active
Set bootnum inactive.
-A | --inactive
Delete bootnum (hex).
-B | --delete-bootnum
Create new variable bootnum and add to bootorder.
-c | --create
Display the help and exit.
-h | --help
Create a netboot entry for the named interface.
-i | --iface name
Set BootNext to XXXX (hex).
-n | --bootnext XXXX
Delete BootNext.
-N | --delete-bootnext
66 Utilities Reference

Table of Contents

Other manuals for HP BL860c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP BL860c and is the answer not in the manual?

HP BL860c Specifications

General IconGeneral
BrandHP
ModelBL860c
CategorySoftware
LanguageEnglish

Related product manuals