Troubleshooting 52
6.
Collect all tools and utilities, such as a Torx screwdriver, loopback adapters, ESD wrist strap, and
software utilities, necessary to troubleshoot the problem.
HP recommends you have access to the server documentation for server-specific information.
Common problem resolution
Loose connections (on page 52)
Service notifications (on page 52)
Firmware updates (on page 52)
DIMM handling guidelines (on page 53)
Hard drive guidelines ("SAS and SATA hard drive guidelines" on page 53)
SAS and SATA hard drive LED combinations (on page 53)
Loose connections
Action:
Be sure all power cords are securely connected.
Be sure all cables are properly aligned and securely connected for all external and internal
components.
Remove and check all data and power cables for damage. Be sure no cables have bent pins or
damaged connectors.
If a fixed cable tray is available for the server, be sure the cords and cables connected to the server
are routed correctly through the tray.
Be sure each device is properly seated. Avoid bending or flexing circuit boards when reseating
components.
If a device has latches, be sure they are completely closed and locked.
Check any interlock or interconnect LEDs that may indicate a component is not connected properly.
If problems continue to occur, remove and reinstall each device, checking the connectors and sockets
for bent pins or other damage.
Service notifications
To view the latest service notifications, refer to the HP website (http://www.hp.com/go/bizsupport).
Select the appropriate server model, and then click the Troubleshoot a Problem link on the product page.
Firmware updates
Download firmware updates from the following locations:
The HP Smart Components available on the HP Support website (http://www.hp.com/support)
The most recent version of a particular server or option firmware from the HP Support website
(http://www.hp.com/support
)
Components for option firmware updates available from the HP Support website
(http://www.hp.com/support
)

Table of Contents

Other manuals for HP ML150 - ProLiant - G6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ML150 - ProLiant - G6 and is the answer not in the manual?

HP ML150 - ProLiant - G6 Specifications

General IconGeneral
Product LineProLiant
ModelML150 G6
Processor Sockets2
Form FactorTower
ChipsetIntel 5520
Hard Drive Form Factor3.5-inch
ProcessorIntel Xeon 5500 series
MemoryUp to 48GB DDR3
Memory Slots12
Expansion Slots6
Power Supply750W
Number of Processors Supported1 or 2 (depending on model)