Troubleshooting 53
HP offers a subscription service that can provide notification of firmware updates. For more information,
see "Subscriber's Choice (on page 44)."
For detailed information on updating firmware, see "Firmware maintenance (on page 84)."
DIMM handling guidelines
CAUTION: Failure to properly handle DIMMs can cause damage to DIMM components and
the system board connector.
When handling a DIMM, observe the following guidelines:
Avoid electrostatic discharge (on page 97).
Always hold DIMMs by the side edges only.
Avoid touching the connectors on the bottom of the DIMM.
Never wrap your fingers around a DIMM.
Avoid touching the components on the sides of the DIMM.
Never bend or flex the DIMM.
When installing a DIMM, observe the following guidelines:
Before seating the DIMM, align the DIMM with the slot.
To align and seat the DIMM, use two fingers to hold the DIMM along the side edges.
To seat the DIMM, use two fingers to apply gentle pressure along the top of the DIMM.
For more information, see the HP website
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c008
68283&jumpid=reg_R1002_USEN).
SAS and SATA hard drive guidelines
When adding hard drives to the server, observe the following general guidelines:
The system automatically sets all drive numbers.
If only one hard drive is used, install it in the bay with the lowest drive number.
Drives must be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.
NOTE: ACU does not support mixing SAS and SATA drives in the same logical volume.
SAS and SATA hard drive LED combinations
NOTE: Predictive failure alerts can occur only when the server is connected to a Smart Array
controller.

Table of Contents

Other manuals for HP ML150 - ProLiant - G6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ML150 - ProLiant - G6 and is the answer not in the manual?

HP ML150 - ProLiant - G6 Specifications

General IconGeneral
Product LineProLiant
ModelML150 G6
Processor Sockets2
Form FactorTower
ChipsetIntel 5520
Hard Drive Form Factor3.5-inch
ProcessorIntel Xeon 5500 series
MemoryUp to 48GB DDR3
Memory Slots12
Expansion Slots6
Power Supply750W
Number of Processors Supported1 or 2 (depending on model)

Related product manuals