Software and configuration utilities 117
Displaying system information
Selecting the primary boot controller
Configuring memory options
Language selection
For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or
the HP website (http://www.hp.com/support/smartstart/documentation).
Using RBSU
To use RBSU, use the following keys:
To access RBSU, press the F9 key during power-up when prompted.
To navigate the menu system, use the arrow keys.
To make selections, press the Enter key.
To access Help for a highlighted configuration option, press the F1 key.
IMPORTANT: RBSU automatically saves settings when you press the Enter key. The utility does
not prompt you for confirmation of settings before you exit the utility. To change a selected setting,
you must select a different setting and press the Enter key.
Default configuration settings are applied to the server at one of the following times:
Upon the first system power-up
After defaults have been restored
Default configuration settings are sufficient for proper typical server operation, but configuration settings can
be modified using RBSU. The system will prompt you for access to RBSU with each power-up.
Auto-configuration process
The auto-configuration process automatically runs when you boot the server for the first time. During the
power-up sequence, the system ROM automatically configures the entire system without needing any
intervention. During this process, the ORCA utility, in most cases, automatically configures the array to a
default setting based on the number of drives connected to the server.
NOTE: The server may not support all the following examples.
NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not
automatically configure the array. You must run ORCA to configure the array settings.
Drives installed Drives used RAID level
1
1
RAID 0
2
2 RAID 1
3, 4, 5, or 6
3, 4, 5, or 6 RAID 5
More than 6
0 None
To change any ORCA default settings and override the auto-configuration process, press the F8 key when
prompted.

Table of Contents

Other manuals for HP ProLiant ML370 G6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML370 G6 and is the answer not in the manual?

HP ProLiant ML370 G6 Specifications

General IconGeneral
ProcessorIntel Xeon 5500 and 5600 series
Processor Sockets2
MemoryUp to 192 GB DDR3
Memory Slots18 DIMM slots
Form Factor5U Tower
StorageUp to 16 SFF drives or 8 LFF drives
Expansion Slots6 total: 2 x8 PCIe Gen2, 2 x4 PCIe Gen2, 1 x8 PCIe Gen2, 1 x4 PCI
NetworkEmbedded Dual Port Gigabit Ethernet
Power SupplyRedundant hot-plug power supplies
Operating System SupportWindows, RHEL, SLES, VMware

Related product manuals