Software and configuration utilities 120
Provides different operating modes, enabling faster configuration or greater control over the
configuration options
Remains available any time that the server is on
Displays on-screen tips for individual steps of a configuration procedure
Beginning with ACU version 8.28.13.0, provides diagnostic functionality on the Diagnostics tab
(formerly known as Array Diagnostics Utility).
For optimum performance, the minimum display settings are 1024 × 768 resolution and 16-bit color. Servers
running Microsoft® operating systems require one of the following supported browsers:
Internet Explorer 6.0 or later
Mozilla Firefox 2.0 or later
For Linux servers, see the README.TXT file for additional browser and support information.
For more information, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the
Documentation CD or the HP website (http://www.hp.com).
Option ROM Configuration for Arrays
Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign
RAID levels, and establish online spare configurations.
The utility also provides support for the following functions:
Reconfiguring one or more logical drives
Viewing the current logical drive configuration
Deleting a logical drive configuration
Setting the controller to be the boot controller
If you do not use the utility, ORCA will default to the standard configuration.
For more information regarding array controller configuration, refer to the controller user guide.
For more information regarding the default configurations that ORCA uses, refer to the HP ROM-Based Setup
Utility User Guide on the Documentation CD.
Re-entering the server serial number and product ID
After you replace the system board, you must re-enter the server serial number and the product ID.
1. During the server startup sequence, press the F9 key to access RBSU.
2. Select the Advanced Options menu.
3. Select Service Options.
4. Select Serial Number. The following warnings appear:
WARNING! WARNING! WARNING! The serial number is loaded into the system during
the manufacturing process and should NOT be modified. This option should only
be used by qualified service personnel. This value should always match the
serial number sticker located on the chassis.
Warning: The serial number should ONLY be modified by qualified personnel.
This value should always match the serial number located on the chassis.
5. Press the Enter key to clear the warning.

Table of Contents

Other manuals for HP ProLiant ML370 G6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML370 G6 and is the answer not in the manual?

HP ProLiant ML370 G6 Specifications

General IconGeneral
ProcessorIntel Xeon 5500 and 5600 series
Processor Sockets2
MemoryUp to 192 GB DDR3
Memory Slots18 DIMM slots
Form Factor5U Tower
StorageUp to 16 SFF drives or 8 LFF drives
Expansion Slots6 total: 2 x8 PCIe Gen2, 2 x4 PCIe Gen2, 1 x8 PCIe Gen2, 1 x4 PCI
NetworkEmbedded Dual Port Gigabit Ethernet
Power SupplyRedundant hot-plug power supplies
Operating System SupportWindows, RHEL, SLES, VMware