HP ProLiant DL140 Server Setup and Installation Guide 56
E
Server Specifications
Operating and Performance Specifications
Table E-1: Operating and Performance Specifications
Dimensions/Feature
Height 4.37 cm (1.72 in)
Depth 60.22 cm (23.7 in)
Width 43.0 cm (16.9 in)
Weight (maximum) 11.00kg (24.2 lb)
Input requirements
Rated input voltage 100 VAC to 240 VAC —
Rated input frequency 50 Hz to 60 Hz —
Rated input current 4.5A (100-120 V) / 2.5A (200-240 V)
Rated input power 440 W —
BTUs per hour 1509 —
Power supply output
Rated steady-state power 325 W —
Maximum peak power 422 W (for max. duration of 15
seconds)
—
Temperature range
1
Operating (See note)
10°C to 35°C (50°F to 95°F)
Shipping (See note)
-40°C to 60°C (-40°F to 140°F)
Relative humidity (noncondensing)
2
Operating (See note) 10% to 90% —
Non-operating (See note) 10% to 95% —
Maximum wet bulb temperature
28°C (82.4°F)
1
Operating temperature has an altitude derating of 1°C per 308.4 M (1.8°F per 1000 ft). No
direct sunlight.
2
Storage maximum humidity of 95 percent based on maximum temperature of 45°C