EasyManuals Logo
Home>HP>Storage>StorageWorks

HP StorageWorks User Manual

HP StorageWorks
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #102 background imageLoading...
Page #102 background image
102 External Storage XP for the XP12000/XP10000
NOTE: When using the Thunder 9500V subsystem as an external disk array, the following versions are
recommended. If you use a 9500V subsystem whose version is earlier than the following versions, the
SATA drive’s information might not be displayed correctly.
For Thunder 9530V, Thunder 9520V, Thunder 9570V: version 0658 or later
For Thunder 9580V, Thunder 9585V: version 1658 or later
Relationship between serial numbers in the Device list on the LU Operation pane and Thunder
9500V subsystem models
When the external disk array is a Thunder 9500V subsystem, you can identify the subsystem model from
the serial number displayed in the Serial column in the Device list on the LU Operation pane.
Inquiry Setting Command Queuing Mode Set this parameter to ON.
Vendor ID Keep this parameter as HITACHI (default),
and do not change.
Product ID Keep this parameter as DF600F (default),
and do not change.
ROM Microprogram Version You can either specify this parameter or
omit specifying this parameter.
RAM Microprogram Version You can either specify this parameter or
omit specifying this parameter.
WEB Title You can either specify this parameter or
omit specifying this parameter.
Port Type Reset/LIP Mode
Reset/LIP Mode (Signal) You can either specify this parameter or
omit specifying this parameter.
Reset/LIP Mode (Process) You can either specify this parameter or
omit specifying this parameter.
LIP Reset Mode You can either specify this parameter or
omit specifying this parameter.
Controller Option RS232C Error Information Outflow Mode You can either specify this parameter or
omit specifying this parameter.
Write and verify mode Set this parameter to ON.
Host Connection Mode Host Connection Mode 1 Set this parameter to Standard Mode.
Host Connection Mode 2 Specify HISUP Mode.
NOTE: Do not specify any other
parameters.
Table 12 System parameter settings (Thunder 9500V subsystems) (continued)
Pane name Parameter Parameter setting

Table of Contents

Other manuals for HP StorageWorks

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks and is the answer not in the manual?

HP StorageWorks Specifications

General IconGeneral
BrandHP
ModelStorageWorks
CategoryStorage
LanguageEnglish

Related product manuals