Path status and examples of recovery procedures (Thunder 9500V subsystems)
Table 15 shows examples of recovery procedures when the path status is not normal. When the path status
is not normal, see ”Troubleshooting External Storage XP” on page 95 and this table to recover the path
status. If you cannot restore the path, contact you HP account support representative.
Table 15 Path status and examples of recovery procedures (Thunder 9500V subsystems)
Path status Examples of recovery procedures
External device setting changed LUN Manager may have changed the LU paths’ settings.
Check the LU paths’ settings. If the LU paths’ settings changed, change the
settings back to the ones used when the volume was mapped. Or use
External Storage XP to perform the Delete LU operation, and perform the
Add LU operation again.
Open LDEV Guard may have changed the volume’s access attribute.
Check the volume’s access attribute. If the volume is protected by the
access attribute, release the protection.
Illegal request The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,
Continuous Access XP, or another copy program. If the volume is set as a
pair volume, the volume might be protected because of the pair status. If
the volume is protected, change the pair status or delete the pair.
Open LDEV Guard may have changed the volume’s access attribute.
Check the volume’s access attribute. If the volume is protected by the
access attribute, release the protection.
Response error The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,
Continuous Access XP, or another copy program. If the volume is set as a
pair volume, the volume might be protected because of the pair status. If
the volume is protected, change the pair status or delete the pair.
Open LDEV Guard may have changed the volume’s access attribute.
Check the volume’s access attribute. If the volume is protected by the
access attribute, release the protection.
Cannot detect port There is a problem with the connection to the external disk array. The
following are possible causes:
• The fibre cable is not connected properly.
• The topology setting between the external and target ports does not
match.
• If the external disk array is connected through switches, the switches’
settings might not be appropriate.
Check if the fibre cable is connected properly, and use LUN Manager to
set the fibre channel port properly.
LUN Manager may have enabled host group security.
Check if host group security is enabled. If host group security is enabled,
disable host group security.