l Cause 1: The disk is badly connected to the backplane.
1. Remove and insert the disk again.
WARNING
l To prevent damaging the disk or the connector, carefully remove the disk or install
the disk with equal force.
l Before inserting the disk, release the handle of the disk to the maximum angle;
otherwise, the disk cannot be fully inserted into the empty slot.
2. If the disk alarm/location indicator is off minutes after you insert the disk again, you
can determine that the fault is caused by bad connection between the disk and the
backplane.
l Cause 2: The disk is faulty.
1. Remove and insert the disk again.
2. If the disk alarm/location indicator is on after you insert the disk again, you can
determine that the disk is faulty.
Procedure
l Cause 1: The disk is badly connected to the backplane.
1. Remove and insert the disk again.
2. After the disk is inserted again, the disk alarm/location indicator is off minutes later.
The fault is handled.
l Cause 2: The disk is faulty.
1. Replace the faulty disk by a new one.
2. After the disk is inserted again, the disk alarm/location indicator is off minutes later.
The fault is handled.
----End
5.5 Turning On of the Fan Running/Alarm Indicator
This section describes how to handle the fault when the fan running/alarm indicator is on.
Symptom
The fan running/alarm indicator on the fan module in the storage system is on.
Possible Causes
One of the following causes may arouse the turning on of the fan running/alarm indicator:
l The fan module is badly connected to the backplane.
l The fan module is faulty.
5 Troubleshooting of Common Faults
OceanStor S2600 Storage System
Troubleshooting
5-10 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 03 (2010-01-28)