OPERATION
HPR130 Manual Gas Instruction Manual 4-7
6
Install consumables
Do not overtighten parts! Only tighten until mating parts are seated.
Clean the current ring
using a cotton swab with
water or 3% hydrogen
peroxide.
Tool part number
104119
Apply a thin film of silicone lubricant on each o-ring.
Install the electrode Install the swirl ring
Install the nozzle and
swirl ring
Install the inner
retaining cap
Install the shield Install the
retaining cap