EasyManuals Logo
Home>Hypertherm>Welding System>HPR130

Hypertherm HPR130 User Manual

Hypertherm HPR130
239 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #176 background imageLoading...
Page #176 background image
HPR130 Manual Gas Instruction Manual 5-53
6
Gas flows continued
P
NP
16. Perform gas leak test
A. Oxygen pressure drop at ____________
psi in 10 minutes ( ____________ bar)
B. Nitrogen pressure drop at ____________
psi in 10 minutes ( ____________ bar)
P
NP
17. Inspect for hose restrictions
P
NP
A. Motor valve hoses
P
NP
B. Gas console to motor valve
P
NP
C. Off-valve to torch body
P
NP
D. Hoses in power track
Cable connections
P
NP
18. Inspect cables
P
NP
A. CommandTHC
P
NP
B. Control cable from off-valve to
gas console
P
NP
C. From ignition console and gas
console to power supply
Ignition console
P
NP
19. Inspect for moisture, dust and
particulates
P
NP
20. Inspect spark gap subassembly
P
NP
21. Inspect torch leads
System grounding
P
NP
22. Inspect for proper system
component grounding
P
NP
23. Inspect connection from cutting
table to workpiece (+) lead
Power supply
P
NP
1. Inspect for particulates and blow out
P
NP
2. Inspect wiring harnesses
P
NP
3. Inspect main contactor
P
NP
4. Inspect pilot arc relay
Coolant system
P
NP
5. Inspect filter element
P
NP
6. Perform coolant flow tes t
A. Coolant flow checked at _________
gallons per minute ( _________ l/min)
Torch main body
P
NP
7. Inspect water tube
P
NP
8. Inspect current ring
P
NP
9. Clean threads on torch front end
P
NP
10. Inspect Vespel torch insulator
P
NP
11. Inspect torch and consumable o-rings
P
NP
12. Verify proper fit of retaining or shield cap
P
NP
13. Inspect hose fittings
P
NP
14. Inspect torch-to-torch-lead connections
Gas flows
P
NP
15. Inspect plumbing from gas supply
P
NP
A. Oxygen
P
NP
B. Nitrogen
P
NP
C. Air
P
NP
D. Nitrogen-Hydrogen
P
NP
E. Argon-Hydrogen
P
NP
F. Inspect compressed air filter system
Preventive Maintenance Protocol Checklist
Customer:
Location:
Contact:
Date:
Hypertherm system:
System serial #:
System arc hours:
(if equipped with an hour meter)
Comments P –
Performed
NP
Not present on system
Preventive maintenance performed by: Date:
General comments and recommendations:

Table of Contents

Other manuals for Hypertherm HPR130

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HPR130 and is the answer not in the manual?

Hypertherm HPR130 Specifications

General IconGeneral
BrandHypertherm
ModelHPR130
CategoryWelding System
LanguageEnglish

Related product manuals