MAX200 Instruction Manual 4-29
9-99
OPERATION
PAC200T/PAC200E Hand Torch
Stainless Steel
200 amps
•
N
2
Plasma / CO
2
Shield
This gas combination is used when surface nitriding and surface oxidation of alloying elements is less
important. Electrode life is extended when using this gas combination.
Piercing above 7/8 inch (22 mm) not recommended.
* If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
Plasma
Gas
Type
Plasma Gas
Pressure
TEST/RUN
Shield
Gas
Type
Shield
Gas
Pressure
Arc
Current
Setting
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Plasma
Gas Inlet
Pressure
Shield
Gas Inlet
Pressure
(Inches) (mm) (psi) (psi) (Inches) (mm) (amps) (volts) (ipm) (mm/min) (sec) (psi) (psi)
3/16 5
N
2
36-40* / 52-56
CO
2
70 1/8 3 200 125 190 4800 0.5 120 90
1/4 6 1/8 3 130 170 4300 1.0
3/8 10 1/8 3 130 125 3200 1.5
1/2 12 1/8 3 135 95 2400 2.0
5/8 15 .157 4 140 70 1800 2.0
3/4 20 3/16 5 140 50 1250 2.5
7/8 22 1/4 6 145 40 1000 3.0
1 25 1/4 6 150 30 760
1-1/4 32 1/4 6 160 15 380
1-1/2 38 1/4 6 170 10 250
Material
Thickness
Torch-to-work
Distance
Travel Speed
(60 SCFH) (220 SCFH)
020918
Shield
020608
Nozzle
020915
Retaining cap
020415
Electrode
020607
Swirl ring