MAX200 Instruction Manual 4-37
9-99
OPERATION
Piercing above 7/8 inch (22 mm) not recommended.
* If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
PAC200T/PAC200E Hand Torch
Aluminum
200 amps
•
H35 Plasma / N
2
Shield
This gas combination (Hypertherm recommends a mixture of 35% hydrogen and 65% argon for the plasma
gas) gives maximum thickness cutting capability, excellent cut quality and excellent weldability. Electrode
life is extended when this combination is used.
Plasma
Gas
Type
Plasma Gas
Pressure
TEST/RUN
Shield
Gas
Type
Shield
Gas
Pressure
Arc
Current
Setting
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Plasma
Gas Inlet
Pressure
Shield
Gas Inlet
Pressure
(Inches) (mm) (psi) (psi) (Inches) (mm) (amps) (volts) (ipm) (mm/min) (sec) (psi) (psi)
3/16 5 H35 36-40* / 62-66
N
2
70 3/16 5 200 130 170 4300 0.5 120 90
1/4 6 3/16 5 130 155 4000 1.0
3/8 10 1/4 6 135 120 3000 2.0
1/2 12 1/4 6 140 100 2550 2.0
5/8 15 1/4 6 145 80 2000 2.5
3/4 20 5/16 8 150 60 1500 2.5
7/8 22 5/16 8 155 50 1250 2.5
1 25 5/16 8 155 40 1000
1-1/4 32 5/16 8 165 26 660
1-1/2 38 5/16 8 170 18 460
1-3/4 44 5/16 8 180 12 300
2 50 5/16 8 185 7 180
Material
Thickness
Torch-to-work
Distance
Travel Speed
(70 SCFH) (290 SCFH)
020918
Shield
020608
Nozzle
020915
Retaining cap
020415
Electrode
020607
Swirl ring