EasyManuals Logo
Home>Hypertherm>Welding System>MAXPRO200

Hypertherm MAXPRO200 User Manual

Hypertherm MAXPRO200
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #65 background imageLoading...
Page #65 background image
MAXPRO200 Instruction Manual 807700 Revision 1 61
Installation
Line disconnect switch
The line disconnect switch serves as the supply-voltage disconnecting (isolating) device. Install this
switch near the power supply for easy access by the operator.
Installation must be performed by a licensed electrician and according to applicable national and local
codes.
The switch should:
Isolate the electrical equipment and disconnect all live conductors from the supply voltage when in
the “OFF” position
Have one “OFF” and one “ON” position clearly marked with “O” (OFF) and “l” (ON)
Have an external operating handle capable of being locked in the “OFF” position
Contain a power-operated mechanism that serves as an emergency stop
Have slow-blow fuses installed for the proper breaking capacity (see table on previous page).
Main power cable
Wire sizes vary based on the temperature rating of the cable insulation and the distance of the unit from the main box.
Use a 4-conductor Type SO input power cable with a conductor temperature rating of 60° C (140° F) or 9 C (194° F).
Installation must be performed by a licensed electrician.
SWITCH BOX
7

Table of Contents

Other manuals for Hypertherm MAXPRO200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm MAXPRO200 and is the answer not in the manual?

Hypertherm MAXPRO200 Specifications

General IconGeneral
BrandHypertherm
ModelMAXPRO200
CategoryWelding System
LanguageEnglish

Related product manuals