6 Power Supply Component Replacement
Figure 81
7. Reconnect the gas supply, and check for leaks at each fitting and hose connection point on the air filter/regulator
assembly.
CAUTION!
Gas supply pressures not within the specifications in the Specifications section of this manual can
cause poor cut quality, poor consumable life, and operational problems.
If the purity level of the gas is too low, or if there are leaks in the supply hoses or connections:
Cut speeds can decrease.
Cut quality can deteriorate.
Cutting thickness capability can decrease.
Consumables life can be shortened.
2
6
4
1
5
3
1 Plastic retainer nut (red)
2 Air filter element
3 Air filter element retaining nut (white)
4 Brass fitting
5 Air filter bowl
6 Drain hose