2-5
SPECIFICATIONS
powermax600 Service Manual
Grounding Requirements
To ensure personal safety, proper operation and to reduce electromagnetic interference (EMI), the
Powermax600 must be properly grounded:
The power supply chassis is electrically conductive and can present a shock hazard if it is not
properly grounded through the line voltage disconnect box.
The power supply must be properly grounded through the power cord according to national or
local electrical codes.
Three-phase service must use a 4-wire cord that includes a protective earth ground.
Also see
Grounding Safety
, in Section 1 of this manual.
A
PMX600.02
Power Cord / Extension Cord
Use a cord that is certified by national or local codes. The cord should be installed by a licensed electrician.
Refer to the length requirements listed below.
Input
Voltage Phase Recommended Cord Gauge Size (mm
2
)
208-240 VAC 1 10 10 10 16 16
230 VAC 3 4 6 6 10 10
400 VAC 3 2.5 2.5 4 6 6
480 VAC 3 4 4 4 4 6
Recommended Cord Gauge Size (AWG)
208-240 VAC 1 8 8 8 6 6
230 VAC 3 12 10 10 8 8
400 VAC 3 14 14 12 10 10
480 VAC 3 12 12 12 12 10
< 10 ft 10-25 ft 25-50 ft 50-100 ft 100-150 ft
< 3 m 3 – 7.5 m 7.5 – 15 m 15 – 30 m 30 – 45 m
10-99

Table of Contents

Other manuals for Hypertherm powermax600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm powermax600 and is the answer not in the manual?

Hypertherm powermax600 Specifications

General IconGeneral
BrandHypertherm
Modelpowermax600
CategoryWelding System
LanguageEnglish

Related product manuals