EasyManuals Logo
Home>Hypertherm>Welding System>powermax600

Hypertherm powermax600 Service Manual

Hypertherm powermax600
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
3-30
MAINTENANCE
powermax600 Service Manual
Work Cable Replacement
Disconnect electrical power and gas supply before removing the old work cable.
Installation - Refer to Figure 3-14.
Install the strain relief (1) to the power supply and secure with nut (2).
Install work cable (3) through the strain relief.
Tie a knot (4) in the end of the work cable.
Tighten the strain relief collar (5) onto the cable.
Connect the work cable to the terminal block (6).
Tighten terminal block screw to 10 in-lb (12 kg cm) of torque.
Install the power supply cover.
Figure 3-14 Work Cable Replacement
CAUTION: This is a high current connection.
Proper torque is critical.
PMX600.15
Early Configuration
10-99

Table of Contents

Other manuals for Hypertherm powermax600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm powermax600 and is the answer not in the manual?

Hypertherm powermax600 Specifications

General IconGeneral
BrandHypertherm
Modelpowermax600
CategoryWelding System
LanguageEnglish

Related product manuals