Failing Item Description Document Description
86G7750 Battery Power Unit Charger Repair and Parts
86G8020 Battery Power Unit Charger Repair and Parts
86G8040 Battery Power Unit Repair and Parts
90H6287 Optical Converter Repair and Parts
ACMODUL AC Module Problem Analysis; Symbolic FRU Isolation
AIRMOVR Fan and Blower assemblies Problem Analysis; Symbolic FRU Isolation
AJDG301 Vertical Licensed Internal Code. Service Functions; APAR or LICTR
ALTMANL Alternate Manual Required Problem Analysis; Symbolic FRU Isolation
BACKPLN Back Plane Unit Problem Analysis; Symbolic FRU Isolation
BATCHGR Battery Power Unit Charger Problem Analysis; Symbolic FRU Isolation
BATRY Battery Power Unit Problem Analysis; Symbolic FRU Isolation
BKSPCN SPCN card Problem Analysis; Symbolic FRU Isolation
BUSPWR Domain 29V Bus Problem Analysis; Symbolic FRU Isolation
CBLALL Cable Failure Problem Analysis; Symbolic FRU Isolation
CLKCARD Clock card Problem Analysis; Symbolic FRU Isolation
CTLPNL Control Panel Problem Analysis; Symbolic FRU Isolation
DISKDRV Disk Unit Power regulator Problem Analysis; Symbolic FRU Isolation
DISKTRY Disk unit tray Problem Analysis; Symbolic FRU Isolation
DMREG Domain Regulator Problem Analysis; Symbolic FRU Isolation
I2CBUS I2C Bus Part Problem Analysis; Symbolic FRU Isolation
IDPART Vital Product Data Parts Problem Analysis; Symbolic FRU Isolation
INTRLCK Interlock part Problem Analysis; Symbolic FRU Isolation
PGDPART Power Good Part Problem Analysis; Symbolic FRU Isolation
PWROC Power Supply overcurrent Problem Analysis; Symbolic FRU Isolation
PWRREG Regulator. Problem Analysis; Symbolic FRU Isolation
PWRSPLY Power Supply Problem Analysis; Symbolic FRU Isolation
RMDEV Disk Unit or Removable Media Device Problem Analysis; Symbolic FRU Isolation
SPNLCRD SPCN panel card Problem Analysis; Symbolic FRU Isolation
SVCPROC Service Processor Card Problem Analysis; Symbolic FRU Isolation
TWRCARD Card enclosure or backplane Problem Analysis; Symbolic FRU Isolation
UPSUNIT UPS unit part Problem Analysis; Symbolic FRU Isolation
VPDPART VPD Communication Part Problem Analysis; Symbolic FRU Isolation
(1xxx) SPCN Reference Codes for Models 870 and 890
If you reached this point from the Service Action Log (SAL), return to the SAL and
display the failing item information for this entry. Go directly to the symbolic FRU
specified in the failing items list.
Note: On Models 870 and 890, the two rightmost characters on the control panel
display (following the dash) are the table identifier (-xx). The table identifier
is required to determine which Model 870 or 890 reference code table
applies to the unit reference code recorded.
1xxx
120
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)