(1xxx) System Power Control Network (SPCN) Reference Codes
The system power control network (SPCN) detected a failure.
Note: The second and third characters of the SRC indicate the frame number of
the failing unit.
1. Look at the four rightmost characters of the SRC for Function 11 or Function 5.
These characters are the unit reference code.
2. Find the unit reference code in the following tables, depending on the system
model.
Note: xSeries Server (formerly Netfinity) frames will have only the frame
number flashing on the failing units PCI (SPCN) card assembly which is
visible after removing the cover.
Choose the model you are working on:
v Models 270 and 820
v Models 800, 810, and 825
v Models 830, 840, SB2, and SB3
v Models 870 and 890
(1xxx) SPCN Reference Codes for Models 270 and 820
For details on the Failing Item column entries, see the SPCN Failing Items Detail
table.
Table 1. SPCN reference codes for Models 270 and 820:
Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
00A0 SPCN BATs in process
No action required. This reference code is logged for information only. If
this reference code is present for more than 1 minute, exchange the failing
items.
TWRCARD
00A1 Regulator 1 has been turned off by system
No action required. This reference code is logged for information only.
00A2 Regulator 2 has been turned off by system
No action required. This reference code is logged for information only.
00A3 Regulator 3 has been turned off by system
No action required. This reference code is logged for information only.
00A4 Regulator 4 has been turned off by system
No action required. This reference code is logged for information only.
00A5 Regulator 5 has been turned off by system
No action required. This reference code is logged for information only.
00A6 Regulator 6 has been turned off by system
No action required. This reference code is logged for information only.
1xxx
10
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference Codes)

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals