Table 2. Common Licensed Internal Code Failing Items Details
Failing Item Description Document Description
AJDG301 Licensed Internal Code Service Functions; APAR or LICTR
AJDGP01 Licensed Internal Code Service Functions; APAR or LICTR
AJDGP01 I/O processor Licensed Internal Code Service Functions; APAR or LICTR
AJEQU00 I/O processor Licensed Internal Code Service Functions; APAR or LICTR
ANYBUS System bus Problem Analysis; Symbolic FRU Isolation
BACKPLN Card enclosure or backplane Problem Analysis; Symbolic FRU Isolation
CDAWKLD Too many communications lines in use
IOACNFG Configuration error Problem Analysis; Symbolic FRU Isolation
SVCDOCS Customer engineer directed to system problem
analysis
Problem Analysis; Symbolic FRU Isolation
SVCPROC Service Processor Card Problem Analysis; Symbolic FRU Isolation
(B070) Reference Codes
1. Look at charcters 5 through 8 of the top 16 character line of function 11 (4
rightmost characters of word 1). These 4 characters are the unit reference code.
2. Find the unit reference code in the following table.
For more on the Failing Item column entries, see Table 2. Failing Items Details,
which follows the reference code table below.
Table 1. (B070) Reference Codes
Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0000 Device no response time-out; temporary error FI00601
FI00602
FI00610
0001 WS IOP detected error when transmitting data
Is the problem intermittent?
No Yes
↓ Perform the following procedures:
1. INT-PIP5
2. INT-PIP14
Perform TWSC-PIP1.
FI00602
FI00601
GAU7777
GAU8888
FI00610
FI00615
0003 WS IOP detected parity error from device
Is the problem intermittent?
No Yes
↓ Perform the following procedures in Intermittent PIPs;
1. INT-PIP5
2. INT-PIP14
Perform TWSC-PIP1.
FI00602
FI00601
GAU7777
FI00610
B006
212
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)