Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0004 Device detected parity error from WS IOP
Is the problem intermittent?
No Yes
↓ Perform the following procedures:
1. INT-PIP5
2. INT-PIP14
Perform TWSC-PIP1.
FI00602
FI00601
GAU7777
FI00610
0005 WS IOP detected error when transmitting data
Is the problem intermittent?
No Yes
↓ Perform the following procedures:
1. INT-PIP5
2. INT-PIP14
Perform TWSC-PIP1.
FI00602
FI00601
GAU8888
FI00610
FI00615
0006 WS IOP detected wrong data from device
Is the problem intermittent?
No Yes
↓ Perform the following procedures:
1. INT-PIP5
2. INT-PIP14
Perform TWSC-PIP1.
FI00601
FI00602
GAU8888
FI00610
0007 WS IOP detected wrong address from device
Is the problem intermittent?
No Yes
↓ Perform the following procedures:
1. INT-PIP5
2. INT-PIP14
Perform TWSC-PIP1.
FI00601
GAU8888
GAU7777
FI00610
0008 WS IOP detected device power turned off, and then on
Perform TWSC-PIP1.
GAUEEEE
FI00601
0009 WS IOP detected wrong device response to start command
Perform TWSC-PIP1.
FI00601
FI00610
0020 Device detected wrong command or device ID from WS IOP
Perform TWSC-PIP1.
FI00601
AJLYD01
FI00610
0021 Device detected not valid value from WS IOP
Perform TWSC-PIP1.
FI00601
AJLYD01
FI00610
B070
System Reference Codes 213